Home » Product List » HID ballast » HID (Direct Current)
Product Details
HID (Direct Current)
| Packing: | Colorful Box, OEM, Aluminum Case |
|---|---|
| Model NO.: | LL-ZL(Only this one is Direct Current) |
| Standard: | HID Xenon Lamp |
| Productivity: | 30000/Month |
| Unit Price/Payment: | Western Union /T/T |
| Trademark: | CARSBO |
| Origin: | GZ, Guangdong, China |
| Min. Order: | 100Sets |
| Transportation: | By Air, Sea, or by express |
Product Description
Model No: LL-ZL
Technical Parameter: (Direct Current)
Input voltage range: DC9~17V
Output power: 35W more or less 0.5W
Working Temperature: -40 degree~105 degree
The difference in temperature: < 30degree
Cold boot current: <6A
Warm boot current: <3.2A
Ignition voltage: 23~25kV
Long lifetime: >3000hours
Open circuit & short circuit protection in 1s
Waterproof, shock-resistant
The Optional modes: Silver & Black
| Model number: | LL-ZL | |||
| Size of ballast: | L 86*W 77.2*H 34.2mm | |||
| Input Voltage: | 9~17V | |||
| Max Start Voltage: | 23kv | |||
| warm boot Current: | 3.2A | |||
| Cold boot current: | <6A | |||
| Output Power: | 35w | |||
| Working Temperature: | 40 Centigrate below zero to 105 Centigrade above zero | |||
| Power Efficiency : | reach 83% | |||
| Working Frequency: | 260~310Hz | |||
| lifetime of ballast: | 3500hours | |||
| The leave factory testing items: | ||||
| 1.6 hours continuous working aging test. | ||||
| 2.Connection circuit protection test. | ||||
| 3.Short circuit protection test. | ||||
| 4.Lack of voltage protection test. | ||||
| 5.over voltage protection test. | ||||
| 6.Flash light concussion test. | ||||
| 7.Quakeproof capability test. | ||||
| 8.cold/warm boot test. | ||||
| 9.Polarity protection test. | ||||
| 10.EMC anti-jamming test. | ||||
Inquiry Basket (